Material
|
Frame: Plastics (Flammability: UL94V-0) Impeller: Plastics (Flammability:Min.UL94V-1)
|
|
Life Expectancy
|
40,000h (L10: Survival rate: 90% at 60 deg C, rated voltage, and continuously run in a free air state)
|
|
Motor Protection System
|
Current blocking function and Reverse polarity protection
|
|
Dielectric Strength
|
50/60 Hz, 500VAC, 1 minute (between lead conductor and frame)
|
|
Sound Pressure Level (SPL)
|
Expressed as the value at 1m from air inlet side
|
Storage Temperature -------------------------------------- Operating Temprature
|
-30 to +70 deg C (Non-condensing) -------------------------------------------------------------------------------------------------------------- -10 to +70 deg C (Non-condensing)
|
|
Lead Wire
|
(+): red (-): black Sensor: yellow Control: brown
|