Maerial
|
Frame: Plastics (Flammability: UL94V-0), Impeller:Plastics (Flammability: UL94V-1)
|
|
Life expectancy
|
40,000 h(Survival rate: 90% at 60º C, rated voltage,and continuously run in a free air state)
|
|
Motor protection system
|
Current cut system (with reverse-connection protection)
|
Dielectric Strength ------------------------------------ Insulation Resistance
|
50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) -------------------------------------------------------------------------------------------------------------- 10M¦¸ or more at 500VDC megger (between lead conductor and frame)
|
|
Noise Measurement Method
|
Measured at 1m from the air inlet
|
Storage Temperature -------------------------------------- Operating Temprature
|
-30ºC to +70ºC -------------------------------------------------------------------------------------------------------------- -10ºC to +70ºC(Non-condensing)
|
|
Lead Wire
|
(+): red (-): black Sencer: yellow
|