Material
|
Frame: Aluminum, Impeller:Plastics (Flammability: UL94V-0)
|
|
Life expectancy
|
100,000 h 9LB1412H501,9LB1412M501 9LB1424H501,9LB1424M501 9LB1448H501,9LB1448M501,9LB1448F501
60,000 h 9LB1412S501 9LB1424S501,9LB1424B501 9LB1448S501 (Survival rate: 90% at 60ºC, rated voltage,and continuously run in a free air state)
|
|
Motor protection system
|
Current cut system (with reverse-connection protection)
|
Dielectric Strength ------------------------------------ Insulation Resistance
|
50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) -------------------------------------------------------------------------------------------------------------- 10M¦¸ or more at 500VDC megger (between lead conductor and frame)
|
|
Noise measurement method
|
Measured at 1m from the air inlet
|
Storage Temperature -------------------------------------- Operating Temprature
|
-30ºC to +70ºC(Non-condensing) -------------------------------------------------------------------------------------------------------------- -10ºC to +70ºC(Non-condensing)
|
|
Lead Wire
|
(+): red (-): black or blue Sensor: yellow
|