Material
|
Frame: Plastics (Flammability: UL94V-0) Impeller: Plastics (Flammability: UL94V-1)
|
|
Life Expectancy
|
60,000h 109P0812C601,109P0812H601,109P0812M601 109P0824H601,109P0824M601
40,000h 109P0848C601,109P0848H601 (L10: Survival rate: 90% at 60º C, rated voltage, and continuously run in a free air state)
|
|
Motor Protection System
|
Current blocking function and Reverse polarity protection
|
Dielectric Strength ------------------------------------ Insulation Resistance
|
50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) -------------------------------------------------------------------------------------------------------------- 10M¦¸ or more at 500VDC megger (between lead conductor and frame)
|
|
Sound Pressure Level (SPL)
|
Expressed as the value at 1m from air inlet side
|
Storage Temperature -------------------------------------- Operating Temprature
|
-30ºC to +70ºC -------------------------------------------------------------------------------------------------------------- -10ºC to +70ºC 109P0812H601,109P0812M601,109P0824H601 109P0824M601,109P0848C601
-10ºC to +60ºC 109P0812C601,109P0848H601 (Non-condensing)
|
|
Lead Wire
|
+: red -: black or blue Sensor: yellow
|